Electromagnetic flowmeter is a type of flowmeter that utilizes Faraday's electromagnetic induction principle. This product adopts the latest international technology and is widely used in industries such as chemical, power, metallurgy, drainage, sewage treatment, liquid high-pressure metering, medicine, food, environmental protection, etc. It is used to measure the volume flow rate of conductive liquids and slurries in closed pipelines.

Features and uses

★ Independence: The measurement is not affected by changes in liquid density, viscosity, temperature, pressure and conductivity;

★ Energy saving and low fault: no moving and blocking parts in the measuring tube, no blockage, no loss;

★ Widely used: conductive liquid, containing fiber, solid particles, suspended liquid;

★ Easy installation: low requirements for straight pipe section (first 5D after 2D);

★ Protection IP68, IP66: DN15~ DN1200, intrinsic immersion structure;

★ High intelligence: backlit LCD display, high integration, double isolation, parameter setting, menu operation. Chinese display, memory function, reliable programming, password lock and access, small signal cutting, non-linear correction, two-way measurement;

★ SMT technology: intelligent self-test and self-diagnosis function, upper and lower limit alarm, excitation alarm, air traffic control alarm;

★ SMART excitation: low power consumption, zero stability, no drift, reliable operation;

★ Multiple output: current output (4~20) mA current, frequency (1~5000)Hz,RS485/Modbus, HART;

★ Lining and electrode: lining and electrode materials have a variety of choices, suitable for different media;

★ Ultra-low EMJ switching power supply: large power supply range, good anti-interference performance;

 

Main Technical Datum

Accuracy:0.5%,1.0%

Repeatability:Not exceeding 1/3 othe absolute maximum of allowable error

Working condition

Sensor

Convertor

Ambient temperature

Separated type

(-20~70)℃

(-20~55)℃

Monomorph

(-20~+55)℃

Relative humidity

Separated type

(5~95)%

( 5~90) %

Monomorph

(5~90)%

Mechanical vibration: frequency (10~55Hz) amplitude 0.20mm

Environmental electromagnetic field :≤300A/m

Medium temperature: related to the lining material, - body type ≤+80℃, take the lowest value of both

Nominal pressure: (0.6~42.0)MPa;

Fluid conductivity :≥5u/cm;

The battery power supply meter must be at least 20 u S/cm;

Power supply :24DC10VA, (85~265)V AC10VA,3.6V lithium battery;

Output signal :4~20mA current, frequency 1~5000Hz,RS485/modbus, HART;

Electrode material :316L stainless steel, Hastelloy, Chin, tantalum, lead carbide, tungsten carbide, Monel;

Lining material: polytetrafluoroethylene, rubber, F46, PVC, polyurethane;

Flange material: carbon steel, can special order other materials.

Measuring catheter :1Cr18Ni9Ti

Explosion-proof class :ExdbebiallCT4/T5Gb

Flange standard :PN6~PN63 GB/T 9119-2010 RF

Class600~Class2500 GB/T 9115-2010 RJ