Sumec menuSumec menu

SUMEC TOUCH WORLD

Global Trading Service Platform for Machinery

search Search
Image
中文
Image
+86 25-84532303
Image
T-world@sumec.com.cn
1 / 5
Fluorine lined electric butterfly valve
iconiconicon
Post RequirementsPost Requirements
Huquan Valve
Huquan Valve icon
View more
Post RequirementsPost Requirements
Huquan Valve
Huquan Valve icon
China
Main Products:
Electric gate valves, electric globe valves, electric butterfly valves, electric ball valves, check valves, regulating valves, fluorine lined butterfly valves and ball valves, ceramic valves, etc.
icon

Product information

Fluorine-lined electric butterfly valve anti-corrosion product details

1.Fluorine-lined electric butterfly valve anti-corrosionOverview:

 

The electric fluorine-lined butterfly valve adopts a PTF-lined butterfly plate with a spherical sealing surface. The valve is easy to operate, has tight sealing performance, and has a long service life; it can be used to quickly cut off or adjust flow. Suitable for applications requiring reliable sealing and good adjustment characteristics. The valve body adopts a split type, and the sealing at both ends of the valve shaft is controlled by the rotating base surface between the butterfly plate and the valve seat and fluorine rubber to ensure that the valve shaft does not come into contact with the fluid medium in the cavity. D971F46 electric fluorine-lined butterfly valve is a polymer material with thick lining technology on the flow parts, valve bodies, butterfly plates, and valve stems. It has excellent corrosion resistance and can be used in any concentration of acids, bases, salts, oxidants, reductants, organic solvents and other media. It is an ideal product for use as interception and regulation equipment on gas, liquid, semi-fluid pipelines and containers in chemical, petroleum, medicine, food, steel smelting, papermaking, hydropower and other systems. It can replace gate valves, Globe valves and other types of shut-off and regulating valves.

  

2. Fluorine-lined electric butterfly valve anti-corrosionPurpose:

 

The fully-lined polytetrafluoroethylene (F4), polychlorotrifluoroethylene (F3) and polyperfluoroethylene propylene (F46) fluoroplastic-lined valves produced by our factory have the advantages of corrosion resistance, no leakage, and long life. Suitable for concentrated sulfuric acid, hydrochloric acid, nitric acid, hydrofluoric acid, aqua regia, various organic acids, strong acids, oxidizing media or high-temperature olefinic sulfuric acid, high-temperature concentrated acetic acid, acid-base alternating, a variety of organic solvents and other highly corrosive media.

 

3. Structural characteristics of D971F46 electric fluorine-lined butterfly valve:

 

1. Small size, light weight, light operation, easy installation and maintenance.
2. Excellent and reliable sealing performance, zero leakage, and long service life.
3. The flow characteristics tend to be straight and the adjustment performance is good.
4. The structure is simple, the switch is quick, and it is turned on and off by 90 °.
5. It can replace the use of various valves such as gate valves, globe valves, plug valves, hose valves and diaphragm valves.
6. Pneumatic and electric devices can be configured according to user requirements to meet the needs of remote control and program control.
7. Changing the lining material of the parts can be suitable for various media.

 

4. Lining material of D971F46 electric fluorine-lined butterfly valve:

 

Polyperfluoroethylene propylene FEP F46 
tetrafluoroethylene-ethylene E-TFE F40 
Soluble PTFE FA 
PTFE F4 
Polyvinylidene fluoride PVDF F2 
Modified polyethylene FRPE PO

 

5. Main outline and connection size of D941F46 electric fluorine-lined butterfly valve:

 

nominal diameter

structure length
(Standard value)

Overall size
(Reference value)

Connection size (standard value)

0.6MPa

1.0MPa

1.6MPa

mm

inch

L

H

H0

A

B

D0

n-φd

D0

n-φd

D0

n-φd

50

2

43

63

438

125

125

110

4-14

125

4-18

125

4-18

65

21/2

46

70

453

125

125

130

4-14

145

4-18

145

4-18

80

3

46

83

478

125

125

150

4-18

160

8-18

160

8-18

100

4

52

105

519

125

125

170

4-18

180

8-18

180

8-18

125

5

56

115

713

325

245

200

8-18

210

8-18

210

8-18

150

6

56

137

749

325

245

225

8-18

240

8-22

240

8-22

200

8

60

164

843

325

245

280

8-18

295

8-22

295

12-22

250

10

68

206

947

363

313

335

12-18

350

12-22

355

12-26

300

12

78

230

1013

363

313

395

12-22

400

12-22

410

12-26

350

14

78

248

1046

363

313

445

12-22

460

16-22

470

16-26

400

16

102

289

1135

363

313

495

16-22

515

16-26

525

16-30

450

18

114

320

1328

465

439

550

16-22

565

20-26

585

20-30

500

20

127

343

1226

546

431

600

20-22

620

20-26

650

20-33

600

24

154

413

1394

546

556

705

20-26

725

20-30

770

20-36

 

6. D941F46 electric fluorine-lined butterfly valve adjusting actuator:

The adjustable electric actuator not only has the function of a switch-type integrated structure, but also can accurately control the valve to accurately adjust the medium flow. Due to limited space, its working principle will not be explained in detail here. The following is a brief explanation of the parameters that need to be noted when selecting adjustable electric actuators.

1. Control signal type (current, voltage)

The control signals of adjustable electric actuators generally include current signals (4~20mA, 0~10mA) or voltage signals (0~5V, 1~10V). The type and parameters of the control signal must be clarified when selecting the type.

2. Working form (electric-open type, electric-close type)

The working mode of the adjustable electric actuator is generally electrically open (taking 4 - 20mA control as an example, the electrically open type means that the 4mA signal corresponds to the valve closing, and the 20mA corresponds to the valve opening), and the other is electrically closed (taking 4-20mA control as an example, the electrically open type means that the 4mA signal corresponds to the valve opening, and the 20mA corresponds to the valve closing). Under normal circumstances, the type of work needs to be clear, and many products cannot be modified after leaving the factory.

3. Loss of signal protection

Loss of signal protection means that when the control signal is lost due to line and other faults, the electric actuator opens and closes the control valve to the set protection value. The common protection values are fully open, fully closed, and kept in place, and it is not easy to modify after delivery. The intelligent electric actuators produced by Ogilvy Valve Control can be flexibly modified through on-site settings, and can set any valve switch position.

All products in the store
Fluorine lined electric butterfly valveAll products in the store
Hard sealed electric flanged butterfly valveAll products in the store
高压高温电站阀门All products in the store
Wind and wind complementary electric valveAll products in the store
Hard sealed electric flanged butterfly valveAll products in the store
Wind and wind complementary electric valveAll products in the store