Intelligent Balance Instrument
icon
Post RequirementsPost Requirements
YHD
YHD icon
View more
Post RequirementsPost Requirements
YHD
YHD icon
China
Main Products:
Intelligent Battery Monitoring System(BMS),Micro Module Data Center, precision air conditioner, Uninterruptible Power Supply (UPS) , Intelligent Precision Distribution Cabinet intelligent balancer, power and environmental monitoring equipment.,Static Transfer Switch (STS).Accumulator or Storage Battery
icon

Product information

Product Introduction: The LC-100SA is an intelligent balance instrument that connects to a handheld PDA via Bluetooth, ensuring a safe distance between human and machine. The main unit is capable of vibration analysis for rotating equipment, bearing diagnosis, and single or double-sided dynamic balancing adjustment of equipment. When used with a device health diagnostic platform system, it can achieve point inspection and quality inspection of equipment before leaving the factory.

Six Major Features: Compact and portable, easy to operate, powerful functions, intelligent diagnosis, long-lasting battery life, and platform interconnection.

Five Major Functions: Vibration analysis, bearing diagnosis, point inspection, data interconnectivity, and dynamic balancing.

Vibration Analysis Fault Diagnosis: The device supports data collection of acceleration, velocity, displacement, temperature, and speed, and can display time and frequency domain waveforms and parameters locally in real-time. The product is supported by various algorithms, including FFT and envelope demodulation. In case of a faulty device, users can perform immediate fault diagnosis on-site.

Bearing Fault Diagnosis: By correctly installing the device and following the operation guidance of the bearing diagnosis module to collect bearing vibration data, automatic diagnosis of bearing operation status can be completed. The diagnosis includes information on the operating status, fault types, and remaining life of the bearing.

Equipment Point Inspection Function: Customizable point inspection plans for multiple devices are possible. Equipment maintenance personnel only need to collect operating data from specified equipment at set times and routes to complete routine equipment maintenance work. Point inspection data will be automatically uploaded to the equipment management platform for digital management. The device also supports multiple measurement detections, dimensionless parameter detections, and manual data recording.

Online Cloud Platform: The measured data from the device can be uploaded to the cloud platform in real-time for interconnection with APP and PC ends, achieving functions such as digital work orders, digital maintenance reports, digital operation reports, digital statistical reports, and fault analysis reports. This enhances the digital management capabilities of enterprises.

On-Site Equipment Dynamic Balancing: Users can quickly perform dynamic balancing adjustments on equipment without changing the original installation conditions. A single dynamic balancing adjustment can remove more than ninety percent of the imbalance and directly generate a dynamic balancing result report.

Dynamic Performance Requirements:

Sensors: Accelerometer, Temperature Sensor

Measurements: Single-axis, capable of simultaneously measuring acceleration (A), velocity (V), displacement (D), envelope, and temperature.

Vibration Sensitivity: 40mV/g

Vibration Range: 50g

Amplitude Linearity: ≤5%

Lateral Sensitivity: <5%

Frequency Response: 1-4.7KHz (±5%); 1-11KHz (±3dB)

Analysis Bandwidth: 100~10K Hz

Spectral Lines: 25600

Vibration Measurement Parameters: Acceleration (Peak) 0.1-500m/s² max

Velocity (RMS) 0.1-200mm/s max

Displacement (Peak-to-Peak) 1-2000 µm max

Vibration Measurement Accuracy: ±5%

Resonant Frequency: 28kHz (typical); 22kHz (minimum)

Vibration Response Time: <100ms

Temperature Response Time: <100ms

Temperature Measurement Range: -50℃ to 380℃

Temperature Measurement Accuracy: 20℃ to 200℃ ±1% or ±1℃ (whichever is greater)

200℃ to 380℃ ±2% or ±2℃ (whichever is greater)

-50℃ to 20℃ ±2% or ±2℃ (whichever is greater)

Distance Coefficient: 12:1

Emissivity: 0.1~1.0 (adjustable)

Laser Aiming: <1mW 650nm Laser Class II

Data Acquisition: Static data (total value), dynamic data (spectrum)

Electrical Characteristics Requirements:

Power Supply Conditions: 3.7V rechargeable lithium battery

Continuous Power Supply Duration: 30 hours (non-continuous vibration acquisition), 10 hours (continuous vibration acquisition)

Indicator Lights: Power indicator, communication indicator

Grounding: The housing is insulated from the signal, with internal shielding

Protective Features: Rubber sheath, insulation, anti-slip, and shock-resistant characteristics.

Communication Characteristics Requirements: 

Communication Method: Bluetooth 

Communication Rate: 1MB/s 

Transmission Time: < 0.6s (1024 points) 

Communication Frequency: 2.4GHz 

Communication Distance: ≤20m

Physical Characteristics Requirements: 

Mass: 200g 

Dimensions: 86mm * 54mm * 23mm

 Mounting Method: Strong magnetic adsorption, 1/4-28UNF thread 

Shock Resistance: Able to withstand a 1-meter drop onto a concrete surface without damage to functionality or the housing

 Protection Rating: IP66

 Explosion-Proof Rating: Ex ib IIC T4 Gb

All products in the store
lead-acid battery(12V100ah)All products in the store
Intelligent Precision Distribution CabinetAll products in the store
Uninterruptible Power Supply (UPS)-High-frequency Tower-Type 10-200kVAAll products in the store
Lead-Acid Battery(12V38AH)All products in the store
lead-acid battery(12V65AH)All products in the store
Data Center Precision Temperature Control(Variable Frequency Room-Level)All products in the store