Sumec menuSumec menu

SUMEC TOUCH WORLD

Global Trading Service Platform for Machinery

search Search
Image
中文
Image
+86 25-84532303
Image
sunyuchen@sumec.com.cn
1 / 2
Uninterruptible Power Supply (UPS) - Offline Line-Interactive Series (DC384V)
icon
Post RequirementsPost Requirements
YHD
YHD icon
View more
Post RequirementsPost Requirements
YHD
YHD icon
China
Main Products:
Intelligent Battery Monitoring System(BMS),Micro Module Data Center, precision air conditioner, Uninterruptible Power Supply (UPS) , Intelligent Precision Distribution Cabinet intelligent balancer, power and environmental monitoring equipment.,Static Transfer Switch (STS).Accumulator or Storage Battery
icon

Product information

Three-in and single-out (DC384) 10KVA-40KVA
Machine kind10KVA15KVA20KVA30KVA40KVA
rated capacity 10KVA / 8KW15KVA / 12KW20KVA / 16KW30KVA / 24KW40KVA / 32KW
Main Road Input Specifications
Input voltage range (Vac)380/400/415 ; 165~280 (Ph-N) / 285~485 (Ph-Ph)
number of phasesThree-phase + neutral + PE
Input frequency range (Hz)50 ±5 (±10%); 60 ±5 (±10%)
Input power factor0.7 (non-filter); ; ≧0.97 (with filter)
rectification technologysilicon control 
Input current harmonic composition (THDI)<50% (non-filter), <15% (plus filter), non-filter / plus filter
Bypass Input Specifications
Input voltage range (Vac)176~264 (Ph-N)
number of phasesThree-phase + neutral + PE
Frequency Tracking Range (Hz)50 ±5(±10%) ; 60 ±5(±10%)
Generator accesssupport
overload capacity150%~180% 1h~300s ; >180% 300s
Output specifications
Output voltage (Vac)220/230/240Vac
Output stability precision±1%
Output active power0.8
Output frequency (Hz)The market power model(50/60) ±0.01HZ
Battery mode(50/60) ±0.01HZ
discharge waveform sinusoidal wave
Output the waveform distortion degreeResistance load≤2%
Nonlinear loading≤4%
Ms cell conversion time (ms)0
productiveness%Line mode 89%; battery mode 90%Line mode 90%; battery mode 91%
overload capacity
≦ 110%60 Minutes
≦ 125%10 Minutes
≦ 150%1Minutes
>150%200 ms
rectification
type6 Pulse
Rated output voltage384 VDC
 charging voltage 395 VDC to 435 VDC (Adjustable)
battery
typeVRLA sealed valve-controlled lead-acid battery
Battery Voltage (Vdc)Section 32 (Section 29 32 can be set); 348 / 360 / 372 / 384 VDC
Charging abilityMaximum = capacity (KW) / battery voltage (real-time), *, the maximum current is never higher than 40A40A, 5A @ full load
Communication and management
Communication functionRS232, USB, RS485, dry contact; 1 slot for the communication card to accommodate the SNMP card
control panel 3.5 inch LCD screen; 7 inch full color touch screen (optional)
Warning functionOutput overload, abnormal mains power, UPS failure, battery low voltage, support historical record query
defencive functionOutput short circuit, output overload, over temperature, battery low voltage, output over undervoltage, fan fault, lightning protection
Other functions
ECO patternsupport
EPO functionsupport
Power supply into the functionsupport
isochronous controller apolegamy
typeVFI-SS-111
Battery charging standardDIN 41773
Parallel number4pcs
environment condition 
working temperature ℃0~40℃
storage temperature ℃-25~55 (excluding battery)
 relative humidity<95% noncondensing
Work altitude0 to 1500m at 100% load
audio-frequency noise 70dB at 100% load
protect
 levels of protection IP20
Three defense coatingsupport
dust gauzeapolegamy
Energy irrigation protectionapolegamy
physical characteristics  
Size (width x depth x height) mm405 x 656 x 817432 x 821 x 1159
weight (kg)118120145193278
operative norm 
safety standardIEC/EN 62040-1-1, IEC/EN 60950-1
electromagnetic compatibilityIEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8, EN55022
performance testing IEC 62040-3
Environmental requirementsIEC 62040-4
 characteristicCE
Chinese market standardsGB/T 14715-2017 ; YD/T 1095-2018

 

Three in and three out (DC384) 10KVA-200KVA
Machine kind10KVA15KVA20KVA30KVA40KVA60KVA80KVA100KVA120KVA160KVA200KVA
rated capacity 10KVA / 8KW15KVA / 12KW20KVA / 16KW30KVA / 24KW40KVA / 32KW60KVA / 48KW80KVA / 64KW100KVA / 80KW120KVA / 96KW160KVA / 128KW200KVA / 160KW
Main Road Input Specifications
Input voltage range (Vac)380/400/415 ; 165~280 (Ph-N) / 285~485 (Ph-Ph)
number of phasesThree-phase + neutral + PE
Input frequency range (Hz)50 ±5 (±10%); 60 ±5 (±10%)
Input power factor0.7 (non-filter); ; ≧0.97 (with filter)
rectification technologysilicon control 
Input current harmonic composition (THDI)<50% (non-filter), <15% (plus filter), non-filter / plus filter
Bypass Input Specifications
Input voltage range (Vac)176~264(Ph-N) ; 304~456 (Ph-Ph)
number of phasesThree-phase + neutral + PE
Frequency Tracking Range (Hz)50 ±5(±10%) ; 60 ±5(±10%)
Generator accesssupport
overload capacity150%~180% 1h~300s ; >180% 300s
Output specifications
Output voltage (Vac)3X380VAC / 400VAC / 415VAC (3 phase + N line)
Output stability precision±1%
Output active power0.8
Output frequency (Hz)The market power model(50/60) ±0.01HZ
Battery mode(50/60) ±0.01HZ
discharge waveform sinusoidal wave
Output the waveform distortion degreeResistance load≤2%
Nonlinear loading≤4%
Ms cell conversion time (ms)0
productiveness%Line mode 89%; battery mode 90%Line mode 90%; battery mode 91%Linear mode 91%; battery mode 92%
overload capacity
≦ 110%60 Minutes
≦ 125%10 Minutes
≦ 150%1Minutes
>150%200 ms
rectification
type6 Pulse
Rated output voltage384 VDC
 charging voltage 395 VDC to 435 VDC (Adjustable)
battery
typeVRLA sealed valve-controlled lead-acid battery
Battery Voltage (Vdc)Section 32 (Section 29 32 can be set); 348 / 360 / 372 / 384 VDC
Charging abilityMaximum = capacity (KW) / battery voltage (real-time), *, the maximum current is never higher than 40A40A, 5A @ full load
Communication and management
Communication functionRS232, USB, RS485, dry contact; 1 slot for the communication card to accommodate the SNMP card
control panel 3.5 inch LCD screen; 7 inch full color touch screen (optional)
Warning functionOutput overload, abnormal mains power, UPS failure, battery low voltage, support historical record query
defencive functionOutput short circuit, output overload, over temperature, battery low voltage, output over undervoltage, fan fault, lightning protection
Other functions
ECO patternsupport
EPO functionsupport
Power supply into the functionsupport
isochronous controller apolegamy
typeVFI-SS-111
Battery charging standardDIN 41773
Parallel number4pcs
environment condition 
working temperature ℃0~55℃
storage temperature ℃-25~55 (excluding battery)
 relative humidity<95% noncondensing
Work altitude0 to 1500m at 100% load
audio-frequency noise 70dB at 100% load
protect
 levels of protection IP20
Three defense coatingsupport 
dust gauzesupport
physical characteristics  
Size (width x depth x height) mm405 x 656 x 817405 x 656 x 941432 x 821 x 1159554 x 975 x 1286635 x 975 x 1326705 x 1051 x 1646
weight (kg)118120145193278365471573650760790
operative norm 
safety standardIEC/EN 62040-1-1, IEC/EN 60950-1
electromagnetic compatibilityIEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8, EN5502
performance testing IEC 62040-3
Environmental requirementsIEC 62040-4
 characteristicCE
Chinese market standardsGB/T 14715-2017 ; YD/T 1095-2018
All products in the store
lead-acid battery(12V100ah)All products in the store
Intelligent Precision Distribution CabinetAll products in the store
Uninterruptible Power Supply (UPS)-High-frequency Tower-Type 10-200kVAAll products in the store
Lead-Acid Battery(12V38AH)All products in the store
lead-acid battery(12V65AH)All products in the store
Data Center Precision Temperature Control(Variable Frequency Room-Level)All products in the store