1 / 1
Uninterruptible Power Supply (UPS) - Offline Line-Interactive Series

Price:
price negotiable
Brand Name:
YHDCountry Region:
ChinaModel No:
6KVA-40KVA


YHD 

Country: China
Main Products: Intelligent Battery Monitoring System(BMS),Micro Module Data Center, precision air conditioner, Uninterruptible Power Supply (UPS) , Intelligent Precision Distribution Cabinet intelligent balancer, power and environmental monitoring equipment.,Static Transfer Switch (STS).Accumulator or Storage Battery
View more
Price:
price negotiable
Brand Name:
YHDCountry Region:
ChinaModel No:
6KVA-40KVA


YHD 

China
Main Products:
Intelligent Battery Monitoring System(BMS),Micro Module Data Center, precision air conditioner, Uninterruptible Power Supply (UPS) , Intelligent Precision Distribution Cabinet intelligent balancer, power and environmental monitoring equipment.,Static Transfer Switch (STS).Accumulator or Storage Battery

Product information
Line-interactive UPS Single-phase Input and Output Series | |||||||
Machine kind | 6kva | 7.5kva | 10kva | ||||
phase position | Single in single out | ||||||
volume | 6KVA/4.8KW | 7.5KVA/6KW | 10KVA/8KW | ||||
input | |||||||
rated voltage | 208VAC/220VAC/230VAC | ||||||
voltage range | 165VAC~285VAC @ 16 batteries; 185VAC~285VAC @ 18 batteries | ||||||
frequency range | From 40 Hz to 55 Hz or 56 Hz to 64 Hz | ||||||
output | |||||||
output voltage | 208VAC/220VAC/230VAC | ||||||
voltage accuracy | ± 1% | ||||||
Frequency range (synchronous correction range) | 45Hz ~ 55 Hz or 56 Hz ~ 64 Hz | ||||||
Frequency Range (battery mode) | 50 Hz±0.1 Hz or 60 Hz±0.1 Hz | ||||||
Current peak ratio | 3:1 | ||||||
Current wave edge ratio | ≤3% (linear load); ≤5% (nonlinear load) | ||||||
transfer time | mains mode to battery mode | / | |||||
Inverse to bypass | / | ||||||
Waveform (battery mode) | pure sine wave | ||||||
productiveness | |||||||
The market power model | 88.3% | ||||||
Battery mode | 92% | ||||||
battery | |||||||
Standard machine | Battery type | 12V/9Ah | |||||
quantity | 16 | ||||||
Standard charging time | 6 hours back to 90%, of the capacity | ||||||
Maximum charging current | 2A | ||||||
charging voltage | 218.4 V±1% | ||||||
Long-term machine | Battery type | Depending on the application | |||||
quantity | 16 | 18 | 16 | 18 | 16 | 18 | |
Maximum charging current | Default: 8A; 2A / 4A / 8A (adjustable) | ||||||
charging voltage | 218.4 V±1% | 245.7 V±1% | 218.4 V±1% | 245.7 V±1% | 218.4 V±1% | 245.7 V±1% | |
show | |||||||
LCD show | UPS status, load level, battery level, input / output voltage and frequency, fault code / warning code | ||||||
Warning voice | |||||||
Battery mode | Vocalization was made once every 4 seconds | ||||||
Low battery power | There is a sound in every second | ||||||
overload | Speak twice per second | ||||||
hitch | Continuous sound | ||||||
physical property | |||||||
Standard machine | Size, deep x width x height (mm) | 592 x 300 x 826 | |||||
Net weight (kg) | 106 | 114 | 122 | 130 | 130 | 138 | |
Long-term machine | Size, deep x width x height (mm) | 592 x 250 x 826 | |||||
Net weight (kg) | 62 | 78 | 86 | ||||
service environment | |||||||
temperature | 0 ~ 50° C~ (temperature higher than 25° C, shortened battery life cycle) | ||||||
humidity | <95%, and not condensing | ||||||
noise | Less than 60 dBA @ 1 m | ||||||
control supervisor | |||||||
Smart RS-232 / USB | Support for Windows® 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10, Linux, Unix, and MAC | ||||||
Dry contact point | Five signals: AC fault, battery insufficiency, UPS alarm, bypass, UPS fault | ||||||
selectable SNMP | SNMP, manager and web browser power management |
Line-Interactive UPS with Three-Input and Single-Output | |||||
Machine kind | 6kva | 10kva | |||
phase position | Single in single out | ||||
volume | 6KVA/4.8KW | 10KVA/8KW | |||
input | |||||
rated voltage | 3 x 360VAC/380VAC/400VAC(3PH+N+G) | ||||
input voltage range | 286VAC~493VAC @ 16 batteries; 320VAC~493VAC @ 18 batteries | ||||
Input frequency range | From 40 Hz to 55 Hz or 56 Hz to 64 Hz | ||||
output | |||||
output voltage | 208VAC/220VAC/230VAC(optional) | ||||
Output stability precision | ± 1% | ||||
Frequency range | 45Hz ~ 55 Hz 或 56 Hz ~ 64 Hz | ||||
Frequency Range (battery mode) | 50 Hz±0.1 Hz 或 60 Hz±0.1 Hz | ||||
Output current peak coefficient | 3:1 | ||||
Output the waveform distortion degree | <3% (linear load); <5% (nonlinear load) | ||||
transfer time | mains mode to battery mode | / | |||
Inverse to bypass | / | ||||
Waveform (battery mode) | pure sine wave | ||||
productiveness | |||||
Communication mode | 83% | ||||
Battery mode | 92% | ||||
battery | |||||
Standard machine | Battery type | 12V/9Ah | |||
quantity | 16 | 16 | |||
Standard charging time | 6 hours back to 90%, of the capacity | ||||
Maximum charging current | 2A | ||||
charging voltage | 218.4 V±1% | ||||
Long-term machine | Battery type | Depending on the application | |||
quantity | 16 | 18 | 16 | 18 | |
Maximum charging current | Default: 8A; 2A / 4A / 8A (adjustable) | ||||
charging voltage | 218.4 V±1% | 245.7 V±1% | 218.4 V±1% | 245.7 V±1% | |
show | |||||
LCD show | UPS status, load level, battery level, input / output voltage and frequency, fault code / warning code | ||||
Warning voice | |||||
Battery mode | Vocalization was made once every 4 seconds | ||||
Low battery power | There is a sound in every second | ||||
overload | Speak twice per second | ||||
hitch | Continuous sound | ||||
physical property | |||||
Standard machine | Size, deep x width x height (mm) | 592 x 300 x 826 | 592 x 360 x 826 | 592 x 300 x 826 | 592 x 360 x 826 |
Net weight (kg) | 129 | 137 | 160 | 168 | |
Long-term machine | Size, deep x width x height (mm) | 592 x300 x 826 | |||
Net weight (kg) | 84 | 115 | |||
service environment | |||||
temperature | 0 ~ 50° C~ (temperature higher than 25° C, shortened battery life cycle) | ||||
humidity | <95%, and not condensing | ||||
noise | Less than 60 dBA @ 1 m | ||||
control supervisor | |||||
Smart RS-232 / USB | Support for Windows® 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10, Linux, Unix, and MAC | ||||
Dry contact point | Five signals: AC fault, battery insufficiency, UPS alarm, bypass, UPS fault | ||||
selectable SNMP | SNMP, manager and web browser power management |
Line-Interactive UPS with Three-Input and Three-Output | ||||||
Machine kind | 10kva | 15kva | 20kva | 30kva | 40kva | |
volume | 10KVA/8KW | 15KVA / 12KW | 20KVA / 16KW | 30KVA / 24KW | 40KVA / 32KW | |
Main Road Input Specifications | ||||||
Input voltage range (Vac) | 380/400/415 ; 165~280 (Ph-N) | |||||
number of phases | Three-phase + neutral + PE | |||||
Input frequency range (Hz) | 50 ±5 (±10%); 60 ±5 (±10%) | |||||
Input power factor | ≧0.7 (non-filter); ≧0.97 (filter) | |||||
rectification technology | silicon control | |||||
Input current harmonic composition (THDI) | <50% (non-filter); <15% (filter) | |||||
Bypass Input Specifications | ||||||
Input voltage range (Vac) | 176~264 (Ph-N) ; 304~456 (Ph-Ph) | |||||
number of phases | Three-phase + neutral + PE | |||||
Frequency Tracking Range (Hz) | 50 ±5(±10%) ; 60 ±5(±10%) | |||||
Generator access | support | |||||
overload capacity | 150%~180% 1h~300s ; >180% 300s | |||||
Output specifications | ||||||
Output voltage (Vac) | 3X380VAC / 400VAC / 415VAC (3 phase + N line) | |||||
Output stability precision | ± 1% | |||||
Output active power | 0.8 | |||||
Output frequency (Hz) | The market power model | (50/60) ±0.01HZ | ||||
Battery mode | (50/60) ±0.01HZ | |||||
discharge waveform | sinusoidal wave | |||||
Output the waveform distortion degree | Resistance load | ≤2% | ||||
Nonlinear loading | ≤4% | |||||
Ms cell conversion time (ms) | 0 | |||||
productiveness% | Line mode 89%; battery mode 90% | Line mode 90%; battery mode 91% | Line mode 91%; battery mode 92% | |||
overload capacity | ||||||
≦ 110% | 60 Minutes | |||||
≦ 125% | 10 Minutes | |||||
≦ 150% | 1Minutes | |||||
>150% | 200 ms | |||||
rectification | ||||||
type | 6 Pulse | |||||
Rated output voltage | 384VDC | |||||
charging voltage | 395 VDC to 435 VDC (Adjustable) | |||||
battery | ||||||
type | VRLA sealed valve-controlled lead-acid battery | |||||
Battery Voltage (Vdc) | Section 32 (Section 29 32 can be set); 348 / 360 / 372 / 384 VDC | |||||
Charging ability | Maximum = capacity (KW) / battery voltage (real-time); the maximum current is never higher than 40A | 40A, 5A @ full load | ||||
Communication and management | ||||||
LCD show | UPS status, load level, battery level, input / output voltage and frequency, fault code / warning code | |||||
Warning voice | ||||||
Communication function | RS232, USB, RS485, dry contact; 1 slot for the communication card to accommodate the SNMP card | |||||
control panel | 3.5 inch LCD screen; 5 inch full color touch screen (optional) | |||||
Warning function | Output overload, abnormal mains power, UPS failure, battery low voltage, support historical record query | |||||
defencive function | Output short circuit, output overload, over temperature, battery low voltage, output over undervoltage, fan fault, lightning protection | |||||
Other functions | ||||||
ECO pattern | support | |||||
EPO function | support | |||||
Power soft up | support | |||||
isochronous controller * | apolegamy * | |||||
type | VFI-SS-111 | |||||
Battery charging standard | DIN 41773 | |||||
Parallel number | 4pcs | |||||
environment condition | ||||||
working temperature ℃* | 0~55℃ | |||||
storage temperature ℃ | 25~55 (excluding battery) | |||||
relative humidity | <95% noncondensing | |||||
Work altitude | 0 to 1500m at 100% load | |||||
audio-frequency noise | 70dB at 100% load | |||||
protect | ||||||
levels of protection | IP20 | |||||
Three defense coating | support | |||||
dust gauze | apolegamy | |||||
Energy irrigation protection | apolegamy | |||||
physical characteristics | ||||||
Size, deep x width x height (mm) | 360 x 557 x 898 | 450 x 687 x 1100 | ||||
Net weight (kg) | 108 | 130 | 146 | 220 | 256 | |
operative norm | ||||||
safety standard | IEC/EN 62040-1-1, IEC/EN 60950-1 | |||||
electromagnetic compatibility | IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8, EN55022 | |||||
performance testing | IEC 62040-3 | |||||
Environmental requirements | IEC 62040-4 | |||||
characteristic | CE | |||||
Chinese market standards | GB/T 14715-2017 ; YD/T 1095-2018 |
All products in the store
lead-acid battery(12V100ah)

Intelligent Precision Distribution Cabinet

Uninterruptible Power Supply (UPS)-High-frequency Tower-Type 10-200kVA

Lead-Acid Battery(12V38AH)

lead-acid battery(12V65AH)

Data Center Precision Temperature Control(Variable Frequency Room-Level)


You May Like


Complete coating and composite production line

Secondary Battery Mixing + Powder Process/Equipment

Coating machine, roller slitting machine

Notching Stacking Tab-welding Packaging

柴油发电机组

Hydrogen production plant

Industrial robot

Lithium battery diaphragm production line

Lithium ion battery automatic assembly line

MicRed Power Tester