Sumec menuSumec menu

SUMEC TOUCH WORLD

Global Trading Service Platform for Machinery

search Search
Image
中文
Image
+86 25-84532303
Image
T-world@sumec.com.cn
1 / 1
Schneider Electric iC65 Micro Circuit Breaker IC65 N 2P C40A
icon
Post RequirementsPost Requirements
Schneider Electric
Schneider Electric icon
View more
Post RequirementsPost Requirements
Schneider Electric
Schneider Electric icon
France
Main Products:
Distribution automation and industrial automation related products
icon

Product information

https://download.schneider-electric.com/files?p_Doc_Ref=scdocmktcncat2025032602&p_enDocType=Catalog&p_File_Name=A9+%E6%A0%B7%E6%9C%AC.pdf

order numberA9F18240

modelIC65N 2P C40A

packaging specifications6 pieces/box, 54Only/box

  • Number of poles: 2P
  • Rated current: 40A
  • Trip characteristics: C
  • Breaking capacity: 6kA
  • Rated voltage: 400VAC
iC65-Micro Circuit Breaker
product nameiC65NiC65N-SiC65HiC65H-SiC65L
meet the standardsIEC/EN60898-1IEC60898-1IEC/EN60898-1IEC60898-1IEC/EN60947-2
GB/T 10963.1GB/T 10963.1GB/T 10963.1GB/T 10963.1GB/T 14048.2
IEC/EN 60947-2 IEC/EN 60947-2 UL1077
GB/T 14048.2 GB/T 14048.2  
  UL1077  
product certificationCCCCCCCCCCCCCCC,CE
CE(1~63A)CE(1~63A)
CCS(1~63A)CCS(1~63A)
 UL(1~63A)
electrical characteristics
number of poles1P,2P,3P,4P1P,2P,3P,4P1P,2P,3P,4P1P,2P,3P,4P1P,2P,3P,4P
Specified current (A)1~801~631~801~631~63
Specified voltage Ue230/400230/400230/400230/400230/400
Rated voltage (V)Ui500500500500500
Maximum operating voltage (V)Umax440440440440440
Minimum operating voltage (V)Umin1212121212
Specified operating frequency (Hz)50/6050/6050/6050/6050/60
Specified impact resistant voltage (KV)Uimp66666
Specified short circuit capability Icn, 230V/400V6kA6kA10kA10kA-
(IEC/EN 60898)
Specified limit short-circuit breaking capacity Icu, 230V/400V6kA-10kA-15kA
(IEC/EN 60947-2)
Specified operating short-circuit interruption power Ics, 230V/400V100%Icu-75%Icu-50%Icu
(IEC/EN 60947-2)
overvoltage categoryIVIVIVIVIV
pollution degree33333
instantaneous tripping characteristicB (3In~5In)-
C (5In~10In)
D (10In~14In)
MA(12In±20%)-----
leakage attachment
Electrical accessories and mechanical accessories
degree of protection against electric shockIIIIIIIIII
mechanical properties
mechanical life2000020000200002000020000
electrical life1000010000100001000010000
protection gradecircuit breaker bodyIP20IP20IP20IP20IP20
Installed in distribution boxIP40IP40IP40IP40IP40
reference setting temperatureGB/T 10963:30°C30°CGB/T 10963:30°C30°C50°C
GB/T 14048:50°CGB/T 14048:50°C
other characteristics
terminal formtunnel typetunnel typetunnel typetunnel typetunnel type
Maximum wiring capacity≤25A2525252525
>25A3535353535
terminal ultimate torque≤25A5.15.15.15.15.1
>25A5.65.65.65.65.6
Touch status indicator (Visi-Safe)--
Fault indication window (Visi-Trip)--
Line entry methodBoth upper and lowerBoth upper and lowerBoth upper and lowerBoth upper and lowerBoth upper and lower

 

All products in the store
Schneider Electric iC65 Micro Circuit Breaker IC65 N 3P C10AAll products in the store
Schneider Electric iC65 Micro Circuit Breaker IC65 N 2P C40AAll products in the store
Schneider Electric iC65 Micro Circuit Breaker IC65 N 2P C16AAll products in the store
Schneider Electric iC65 Micro Circuit Breaker IC65 N 2P C10AAll products in the store
Schneider Electric iC65 Micro Circuit Breaker IC65 N 1P C16AAll products in the store
Schneider Electric iC65 Micro Circuit Breaker IC65 N 2P C20AAll products in the store