Measurement Principle and Application Characteristics
The measurement method is based on radiation transmission and absorption, with the directly measured physical quantity being areal density (grammage). When X-rays penetrate a material, they are reflected, scattered, or absorbed by the material, leading to a certain degree of attenuation in radiation intensity. This attenuation is positively correlated with the areal density of the penetrated material.
When the bulk density of a material is constant or highly consistent, the material's thickness can be measured by converting from the bulk density (Areal Density = Density * Thickness).
The X-ray thickness gauge is a low-energy radiation device. The X-rays can be turned on and off via the power supply, generally requiring no special protection.
The X-ray thickness gauge typically uses an O-type scanning frame.
X-ray Measurement Sensor
The X-ray emitter employs a dual closed-loop circuit control system, ensuring long-term stability of radiation intensity and high measurement repeatability.
The X-ray detector incorporates advanced pre-amplification circuit technology, providing a high signal-to-noise ratio.
The X-ray emitter features a proprietary slit-type radiation collimation channel and a small spot design. Combined with the high signal-to-noise ratio detector and software algorithms, it delivers higher spatial resolution accuracy and better identification of streak defects.
Technical Features and Powerful Functional Modules of X-ray Areal Density Gauges / Thickness Gauges
A new generation of online measurement software system, custom-developed by software architects and big data experts, offering more powerful functions and more scientific algorithms.
Capable of scan measurement, fixed-point measurement, and cyclic fixed-point measurement, with free switching between scanning and fixed-point modes.
Real-time display of various measurement curves such as single/multiple profile lines, zone lines, and trend lines, along with multiple quality data displays.
Comprehensive full-value data storage in Excel format based on a database, enabling historical data query and traceability, and replay of historical curves.
Professional-grade SPC statistical analysis, automatic generation of quality coil reports, customizable according to customer requirements.
Multiple process control solutions, including real-time process monitoring, five-line quality control, multiple warnings and alarms, and out-of-tolerance marking.
Supports closed-loop automatic control, can interface with customer MES systems, and enables multi-stand same-point tracking measurement.
Self-developed data acquisition cards and control boards, real-time communication systems, and CANOPEN bus communication transmission ensure high-speed measurement response.
Enhanced ease of use and a friendly human-machine interface with one-touch intelligent operation.
Application Fields
Online measurement and control of areal density (thickness) uniformity for various sheets, webs, or coatings, such as plastic films, non-wovens, metal foils, rubber, etc.