hot blast stove
Hot blast stoves are thermal energy conversion equipment that uses fuels (blast furnace gas, coke oven gas, converter gas, mixed gas, producer gas, calcium carbide furnace gas, natural gas, petroleum liquefied gas, diesel oil, heavy oil, pulverized coal and garbage, etc.) to burn in the furnace to release chemical energy, heating low-temperature air to high-temperature air at a certain temperature.hot blast stoveOther heat energy (such as electricity, waste heat) can also be used to heat the air.
Performance characteristics:
1. It is widely applicable to fuel varieties. It can be used to make fuels such as blast furnace gas, coke oven gas, converter gas, mixed gas, producer gas, natural gas, petroleum liquefied gas, chemical waste gas, heavy oil, diesel, pulverized coal and other fuels.hot blast stove。
2. The output hot air temperature is controlled, and the temperature difference is within ±5℃.
3. Aiming at the temperature of the control point, the supply of fuel and air is automatically adjusted, making it easy to use.
4. Non-standardized design is highly targeted and can better meet user requirements.
5. The output hot air temperature control range is wide, which can be applied to the drying needs of different industries.
6. It can continuously provide constant temperature, constant pressure and purified hot air.
7. Fully automatic operation, using imported electrical components, high operation reliability and accuracy, and can be networked with industrial configuration control.
Technical performance table:
item of model number | heating capacity | design gas volume | amount of gas | Power regulation range | thermal efficiency |
WRF50T-Z | 50X10⁴ | 60 | 20-70 | 200-700 | >95 |
WRF100T-Z | 100X10⁴ | 120 | 40-140 | 400-1300 | >95 |
WRF200T-Z | 200X10⁴ | 240 | 60-300 | 700-2600 | >95 |
WRF300T-Z | 300X10⁴ | 360 | 100-400 | 1100-4000 | >95 |
WRF400T-Z | 400X10⁴ | 480 | 150-550 | 1400-5200 | >95 |
WRF500T-Z | 500X10⁴ | 600 | 200-650 | 1800-6500 | >95 |
WRF600T-Z | 600X10⁴ | 720 | 250-800 | 2000-8000 | >95 |
WRF800T-Z | 800X10⁴ | 960 | 300-1100 | 2800-10000 | >95 |
WRF1000T-Z | 1000X10⁴ | 1200 | 400-1400 | 3500-13000 | >95 |
WRF1200T-Z | 1200X10⁴ | 1440 | 450-1600 | 4200-16000 | >95 |
WRF1500T-Z | 1500X10⁴ | 1800 | 500-2000 | 5500-20000 | >95 |
WRF2000T-Z | 2000X10⁴ | 2400 | 750-2700 | 7000-25000 | >95 |
WRF2500T-Z | 2500X10⁴ | 3000 | 900-3300 | 9000-32000 | >95 |
WRF3000T-Z | 3000X10⁴ | 3600 | 1100-4000 | 11000-40000 | >95 |
WRF3500T-Z | 3500X10⁴ | 4200 | 1300-4800 | 13000-45000 | >95 |
WRF4000T-Z | 4000X10⁴ | 4800 | 1500-5500 | 14000-50000 | >95 |
WRF4500T-Z | 4500X10⁴ | 5400 | 1700-6000 | 16000-60000 | >95 |
WRF5000T-Z | 5000X10⁴ | 6000 | 1800-6600 | 1 8000-65000 | >95 |
| Note: ① Take Qdw=8500Kcal/Nm³ natural gas, horizontal direct-fired hot blast stove as an example ② Product specifications can also be designed according to user requirements | |||||